Close
Enquiry List

There are currently no items in your enquiry list

Simply add to the list from the product pages to enquire about multiple items on the site.

View Products

VPFlowScope M Thermal In-Line

A next-generation 4-in-1 thermal mass flow meter featuring the proprietary VPSensorCartridge® — enabling on-site recalibration in minutes without downtime. Measures bi-directional flow, pressure, temperature, and total flow simultaneously in 1", 1.5", and 2" line sizes. Built for permanent monitoring, energy management, and lowest total cost of ownership.

The VPFlowScope® M Thermal In-line is the ideal flow meter for point-of-use consumption measurements of compressed air and other industrial gases, including nitrogen, oxygen, CO2, helium, argon and more.

Thanks to our proprietary Thermabridge™ technology, you can measure bi-directional flow, pressure, temperature, and total flow simultaneously. The VPFlowScope M Thermal In-line is perfect for smaller diameters, as can be found in the demand side of your air/gas network, at the point of use, as well as in small to medium sized compressed air systems. It provides all the data you need to optimize your consumption. Whether standalone or integrated into an energy management system like VPVision, there is a version to fit your needs.

The power of a complete solution

Measure bi-directional flow, pressure, and temperature simultaneously for a comprehensive overview. For example, identify if pressure drops result from excessive flow or explore ways to reduce air consumption while maintaining the required pressure level. Avoid mis-readings in e.g. overseen branches or a leaking non-return valve with the powerful bi-directional flow measurements. Always with high accuracy backed by an inclusive calibration report. There are no hidden costs.

VPCartridgeSwap+

Swap. Return. Earn.

Keep your VPFlowScope M in top condition with fast, cost-effective, and sustainable maintenance. Unlike traditional flow meters that require off-site recalibration, resulting in removal, shipping delays, and measurement downtime. The VPFlowScope M enables on-site recalibration in just minutes with a simple VPSensorCartridge swap. No downtime. No disruption. Just accurate data.

Modular Transmitter. Many possibilities!

The versatile Transmitter connects seamlessly to traditional 4..20mA networks, RS485, or modern Power over Ethernet. Multiple versions are available for tailored applications.

Ease of Connection

Reduce installation costs by using Modbus daisy chains or the Power over Ethernet output to connect you VPFlowScope flow meters to VPInstruments’ VPVision energy monitoring system or to your BMS. For robust connection possibilities, VPInstruments offers several plug and play junction and I/O boxes.

Highlights
  • Proprietary VPSensorCartridge® — one cartridge fits all sizes 1" to 2", field-swappable in minutes for on-site recalibration with zero downtime
  • Patented Thermabridge™ technology for dry, clean gas measurements
  • 4-in-1: bi-directional flow (standard), pressure, temperature, totalized flow
  • Modular transmitter — choose S01 (4–20mA + RS485 Modbus RTU) or S03 (Power over Ethernet / Modbus TCP)
  • TFT color display with alarm and status LEDs (optional)
  • 1-year circular data logger, 1-second logging interval (optional)
  • Available in 1", 1.5", and 2" tubing with BSP and NPT thread variants
  • IP65 / NEMA 4 when mated to transmitter
  • Connects to VPVision energy monitoring platform or existing BMS via Modbus daisy chain or PoE
  • Free VPStudio software for configuration, data readout, and reporting
  • VPCartridgeSwap+ program: return used cartridges for refund voucher — 1 returned cartridge = 1 tree planted
  • 1 Year Warranty

Technical Specifications

Parameter

Specification

FLOW SENSOR

Measuring Principle

Thermabridge™ Thermal Mass Flow Sensor

Flow Range 1"

0 – 250 m³n/hr / 0 – 156 SCFM (cutoff at 1.0 m³n/hr)

Flow Range 1.5"

0 – 600 m³n/hr / 0 – 374 SCFM (cutoff at 2.5 m³n/hr)

Flow Range 2"

0 – 1000 m³n/hr / 0 – 623 SCFM (cutoff at 4.0 m³n/hr)

Bi-directional Flow

Standard

Accuracy (forward)

2% of reading + 0.3% full scale

Accuracy (reverse)

5% of reading + 0.3% full scale

Reference Conditions

0°C / 1013.25 mbar (DIN1343), 20°C / 1000 mbar (ISO1217 FAD), 15°C / 1013.25 mbar (ISO2533) — selectable on display

Gases

Compressed air, nitrogen and inert non-condensing gases

Gas Temperature Range

0 – 50°C / 32 – 122°F

PRESSURE SENSOR

Range

0 – 16 barg / 0 – 234 psi

Accuracy

100 mbar / 1.5 psi

TEMPERATURE SENSOR

Range

0 – 50°C / 32 – 122°F

Accuracy

>10 m/sec: ±1°C / ±1.8°F — <10 m/sec: +5°C / +9°F

MECHANICAL — CARTRIDGE

Weight

48g / 1.7 oz

Process Connection

Quick Connect bayonet fitting with tubing

Pressure Rating

PN16

IP Rating

IP65 / NEMA 4 when mated to transmitter

Ambient Temperature

-20 – 60°C / -4 – 140°F

Wetted Materials

Chromated aluminum, SS316L, NBR rubber, glass, epoxy, silicon

TECHNICAL SPECIFICATIONS — Transmitter

Parameter

S01 (Modbus)

S03 (PoE)

Display

1.8" TFT, optional

1.8" TFT, optional

Data Logger

1-year circular, optional

1-year circular, optional

Output

4–20mA, RS485 Modbus RTU

Power over Ethernet, Modbus TCP

USB

Mini USB (configuration)

Mini USB (configuration)

Power Supply

14–24 VDC ±10%, Class 2 (UL)

PoE IEEE P802.3af

Power Consumption

1W (no flow) / 3.5W (full flow)

1.5W (no flow) / 4W (full flow)

Dimensions

50 × 108 × 36 mm / 1.97 × 4.25 × 1.42"

same

Weight

179g / 6.3 oz

194g / 6.8 oz

Housing

Anodized aluminum, polycarbonate cover, NBR O-ring seals

same

IP Rating

IP53 / NEMA 5 (screen facing upward)

same

Certifications

CE EN60950-1, EN61326-1, EN61000-3-2/3-3; UL 508

same

TUBING DIMENSIONS

Size

Length

Weight

1"

500 mm / 19.7"

1.24 kg / 43.7 oz

1.5"

600 mm / 23.6"

2.17 kg / 76.5 oz

2"

750 mm / 29.6"

3.71 kg / 130.9 oz

Ordering Information

Cartridge

Order Code

Description

VPM.R120.PC01.PN16

VPSensorCartridge 1"–2" for flow, pressure, temperature, total flow. Bayonet fitting. Includes 10-point calibration certificate.

Tubing — BSP

Order Code

Description

VPA.1201.010

Tubing 1" BSP

VPA.1201.015

Tubing 1.5" BSP

VPA.1201.020

Tubing 2" BSP

Tubing — NPT

Order Code

Description

VPA.1201.110

Tubing 1" NPT

VPA.1201.115

Tubing 1.5" NPT

VPA.1201.120

Tubing 2" NPT

Transmitters — S01 (4–20mA + Modbus RTU)

Order Code

Description

VPM.T012.D000.S01

Transmitter, no display, Modbus RS485 + 4–20mA/Pulse/Alarm

VPM.T012.D010.S01

Transmitter, with display, Modbus RS485 + 4–20mA/Pulse/Alarm

VPM.T012.D011.S01

Transmitter, display + datalogger, Modbus RS485 + 4–20mA/Pulse/Alarm

Transmitters — S03 (Power over Ethernet / Modbus TCP)

Order Code

Description

VPM.T012.D000.S03

Transmitter, no display, PoE Modbus TCP

VPM.T012.D010.S03

Transmitter, with display, PoE Modbus TCP

VPM.T012.D011.S03

Transmitter, display + datalogger, PoE Modbus TCP

Cables & Power

Order Code

Description

VPA.5000.005

Cable 5m / 16.4ft — M12 5-pin one side, open wires other side (S01)

VPA.5000.010

Cable 10m / 32.8ft — M12 5-pin one side, open wires other side (S01)

VPA.0000.200

Power supply adapter — 110–240 VAC to 24 VDC, M12 5-pin connector

VPA.5004.0005

Ethernet cable 5m / 16.4ft — M12 4-pin to RJ45 (S03)

VPA.0000.160

PoE injector — powers one flow meter, non-PoE Ethernet output, 100–240V input

Other

Order Code

Description

VPA.5014.004

Explorer carry case for VPFlowScope M Thermal In-Line & Probe

VPA.0001.915

Special gas calibration (non-helium) — includes calibration certificate

VPA.0001.912

Helium gas calibration — includes calibration certificate

VPA.0001.913

Additional special gas calibration for additional units, same order

VPA.0001.087*

Gas correction factor (up to 3 gas types pre-set at production)

*Available for argon, CO₂, corgon/protegon 18%. Not available in combination with gas calibration. Consult sales for other gases.

For further information on our comprehensive range of products and services please get in touch with us by visiting our contact page.